Centrifugal Fan in the Al­fried-Krupp hos­pi­tal

A joint aim: peo­ple's health is the top pri­or­ity

The Al­fried-Krupp hos­pi­tal in Es­sen is not just state of the art from a med­ical point of view but is also ex­tremely well equipped in the in­fra­struc­ture area. Peo­ple’s health is the top pri­or­ity and the hos­pi­tal staff’s per­for­mance is sig­nif­i­cant. Clean air is the ba­sis for op­ti­mum per­for­mance in the op­er­at­ing the­atre, as the best air qual­ity en­sures safety for the pa­tients and the op­er­at­ing staff.

A suit­able centrifugal fan from Scheuch COM­PO­NENTS was in­stalled af­ter con­sid­er­ing nu­mer­ous in­flu­enc­ing fac­tors such as room tem­per­a­ture, mois­ture and the noise level.

To the centrifugal fans

Custom-made centrifugal fan 1

Custom-made centrifugal fan 3

Custom-made centrifugal fan 2

Per­form bet­ter

Germ-free air to ensure hygienic conditions

Germ-free air in op­er­at­ing the­atres, the op­er­at­ing area and the setup zones does not just re­duce the risk of post­op­er­a­tive in­fec­tions, but also the risk of death. Fur­ther­more, the time that the pa­tient re­mains in hos­pi­tal is short­ened and this con­tributes to faster pa­tient re­cov­ery. The qual­ity of the clean air sys­tem is de­ci­sive for guar­an­tee­ing these con­di­tions. The Scheuch COM­PO­NENTS centrifugal fan en­sures that this clean air is pro­vided and there­fore en­sures the op­ti­mum hy­gienic con­di­tions in the med­ical fa­cil­ity.

An es­sen­tial com­po­nent

Centrifugal fan with belt drive & two-sided intake port

In­stead of the new fan, there was an older model that was ob­so­lete and no longer met the re­quire­ments. The chal­lenge was to de­sign a new fan that was not just more ef­fi­cient but that also fit­ted into the nar­row space in the lo­ca­tion.

The ex­perts from Scheuch COM­PO­NENTS de­vel­oped a tai­lor-made so­lu­tion that is de­signed es­pe­cially for the avail­able space. The centrifugal fan with belt drive and two-sided in­take port en­ables us to use the lim­ited space op­ti­mally and there­fore to en­sure ef­fi­cient ven­ti­la­tion. The pre­cise de­sign of the fan fit­ted into the ex­ist­ing sit­u­a­tion seam­lessly and there­fore, in­stal­la­tion ran smoothly.

Per­for­mance data

Scheuch COMPONENTS centrifugal fan

Op­er­at­ing flow rate: 32,000 Am³/​​h
Pres­sure in­crease: 3,100 Pa
Mo­tor power: 55 kW
Ref­er­ence in­take tem­per­a­ture: 20 °C
Type of drive: V-belt drive
Con­veyed medium: clean gas
Type of con­struc­tion: two-sided in­take

To the centrifugal fans
Performance data of the centrifugal fans
Questions and answers

In­ter­view with Thorsten Kaipl

Thorsten Kaipl
Head of Division Retrofit Solutions
Rosenberg Ventilatoren GmbH

Why did you choose Scheuch COMPONENTS?
Thanks to my per­sonal con­tact with Mr Ingo Sobotta, whom I al­ready knew from the past, it was easy to choose Scheuch COM­PO­NENTS. How­ever, the de­ci­sive fac­tors were the out­stand­ing qual­ity, the com­pre­hen­sive ad­vice and the at­trac­tive price-per­for­mance ra­tio.

How would you describe the collaboration with Scheuch COMPONENTS? Were there any particular highlights during the course of the project?
The col­lab­o­ra­tion was ex­cel­lent. I would par­tic­u­larly like to em­pha­sise the speedy ex­e­cu­tion. We were faced with a time prob­lem that was solved ef­fi­ciently and in a so­lu­tion-ori­en­tated man­ner. The en­tire process ran smoothly and pro­fes­sion­ally.

Were there any aspects of the collaboration or the design of our fan that you think could be improved?
Every­thing went ex­tremely well with this first or­der. Of course, larger pro­jects can pose chal­lenges, but I am con­vinced that we will al­ways find a suit­able so­lu­tion to­gether.

Are you planning any other projects involving Scheuch COMPONENTS?
In this par­tic­u­lar case, we needed a fan with very high pres­sure, which is a rare re­quire­ment. If we have such re­quire­ments again in the fu­ture, I would def­i­nitely go back to Scheuch COM­PO­NENTS.

Is there anything else you would like to tell us?
Thank you again for the great sup­port. We re­ally ap­pre­ci­ate the col­lab­o­ra­tion and look for­ward to any pos­si­ble fu­ture pro­jects.

Our part­ner

Rosenberg Ventilatoren GmbH

Rosen­berg Ven­ti­la­toren GmbH has spe­cialised in pro­duc­ing and de­vel­op­ing con­trol­lable ex­ter­nal ro­tor mo­tors, fans and air han­dling units since 1981. With pro­duc­tion lo­ca­tions and sales branches in more than 45 coun­tries, the com­pany has a pres­ence around the world. The head­quar­ters are in Baden-Würt­tem­berg, where around 500 peo­ple are em­ployed. In to­tal, Rosen­berg Ven­ti­la­toren GmbH em­ploys around 1,500 peo­ple around the world in 14 pro­duc­tion lo­ca­tions on four con­ti­nents.

Rosenberg logo

Contact us

We will take care of your request.

Sabine Pupeter, contact person at Scheuch COMPONENTS

Send us your message. The responsible contact person will get back to you promptly.